| Data Center Facilities |
The Planet's DLLSTX2, 1333 North Stemmons Freeway, Dallas, TX
- 60,000 sq. ft. facility
- 35,000 sq. ft. of raised floor
- (21) 26-ton Data Air AC units
- Very Early Smoke Detection Apparatus (VESDA)
- Pre-action dry pipe sprinkler system
- Over 500 smoke detectors in an integrated system
- Simplex security badge entry/exit on all doors to facility
|
- Multiple TXU electrical grids
- 4800 amps of 480v input power
- 3 main transfer switches
- (6) 500KVA Powerware UPS units with 90 batteries per unit
- Standalone PDUs at each cabinet row
- 1-megawatt generator (2000-gallon tank)
- 1.5-megawatt generator (2200-gallon tank)
- DataTrax monitoring software for all data center infrastructure
|
|
| |
The Planet's DLLSTX4, 400 South Akard Street in Downtown, Dallas, TX
- 22,000 sq. ft. facility
- 18,000 sq. ft. of raised floor
- (12) 26-ton Data Air AC units
- Very Early Smoke Detection Apparatus (VESDA)
- Pre-action dry pipe sprinkler system
- Over 220 smoke detectors in an integrated system
- Simplex security badge entry/exit on all doors to facility
|
- TXU fault tolerant electrical grid
- 2000 amps of 480v input power
- 1 main transfer switch
- (2) 500KVA Powerware UPS units with 90 batteries per unit
- Standalone PDUs at each cabinet row
- 1.5-megawatt generator (2200-gallon tank)
- DataTrax monitoring software for all data center infrastructure
|
|
| |
The Planet's DLLSTX5, 1950 North Stemmons Freeway, Dallas, TX
- 51,000 sq. ft. facility
- 30,000 sq. ft. of raised floor
- (25) 26-ton chilled water units
- Very Early Smoke Detection Apparatus (VESDA)
- Pre-action dry pipe sprinkler system
- Over 400 smoke detectors in an integrated system
- Multiple TXU fault tolerant electrical grid
- Northern Proximity security badge entry/exit on all doors to facility
|
- 5200 amps of 480v input power
- 3 main transfer switches
- (6) 500KVA Powerware UPS units with 90 batteries per unit
- Standalone PDUs at each cabinet row
- 3.5-megawatts of generator capacity
- DataTrax monitoring software for all data center infrastructure
|
|
| |